CT-Guided Crimping Increases Commissural Alignment in Balloon-Expandable
Intentionally orienting transcatheter aortic valve neo-commissures during crimping based on computed tomography measurements significantly increased the rate of commissural alignment in balloon-expandable transcatheter heart valves compared to standard implant
Illustrative imageIntentionally orienting transcatheter aortic valve neo-commissures during crimping based on computed tomography measurements significantly increased the rate of commissural alignment in balloon-expandable transcatheter heart valves compared to standard implantation methods, according to a clinical investigation published in Structural Heart. In a single-center comparative cohort of 202 patients receiving the Edwards SAPIEN 3 Ultra Resilia valve, deploying the valve with the novel Shenoda-Blocker Commissural Alignment technique achieved commissural alignment in 64.4 percent of cases, representing 65 of 101 patients. In contrast, the control cohort of 101 sequentially treated historical patients managed with standard crimping and valve deployment protocols achieved commissural alignment in only 30.7 percent of procedures, or 31 of 101 patients, a difference that demonstrated strong statistical significance with a p-value of less than 0.001 and a 95 percent confidence interval spanning 0.197 to 0.476.
Commissural alignment has emerged as an important technical objective within modern transcatheter aortic valve replacement literature, yet standard alignment protocols for balloon-expandable systems approved by the United States Food and Drug Administration have historically remained unestablished. The investigators evaluated whether tailoring the orientation of one neo-commissure prior to device insertion could reliably account for the rotational behavior of delivery systems as they traverse patient anatomy. To address this question, the researchers prospectively enrolled 101 patients scheduled for transfemoral transcatheter aortic valve replacement with the Edwards SAPIEN 3 Ultra Resilia transcatheter heart valve and systematically evaluated procedural outcomes against retrospective controls.
Preprocedural planning for all prospective participants relied on dedicated preprocedural computed tomography imaging, which operators analyzed using 3mensio software version 10.6 from Pie Medical Imaging. By measuring each patient’s specific aortic valve plane and aortic root angulation on computed tomography reconstructions, the clinical team established a predetermined orientation for crimping one of the valve’s neo-commissures on the Edwards SAPIEN 3 crimper. The crimping alignment was calibrated directly to the anatomical angles of the patient’s aortic root, positioning the marked neo-commissure at a specified clock orientation, such as the 3:30 position, prior to mounting onto the Edwards Commander Delivery System.
Procedures were carried out by one of two high-volume structural interventional cardiology operators partnering with one of three participating cardiothoracic surgeons. Immediate anatomical alignment of the deployed prosthesis was evaluated inside the catheterization laboratory using intraprocedural transesophageal echocardiography, with all imaging measurements independently verified by a structural imaging echocardiographer. The researchers strictly excluded candidates who lacked intraprocedural transesophageal echocardiography or required non-femoral alternative vascular access routes. The comparative control group consisted of the previous 101 sequential patients who had undergone transfemoral balloon-expandable valve implantation with standard non-oriented crimping and had received matching intraprocedural transesophageal echocardiographic assessments.
Baseline clinical characteristics remained comparable across the prospective study group and the retrospective control cohort. The study and control populations demonstrated similar average ages as well as equivalent prevalence rates of significant coexisting medical conditions, including systemic hypertension, peripheral artery disease, atrial fibrillation, and severe left ventricular systolic dysfunction characterized by a left ventricular ejection fraction of less than 35 percent. Statistical analyses between the two cohorts were conducted utilizing two-sample proportions chi-square testing under an institutional review board approval that granted a waiver of individual patient consent.
Alignment was classified according to standard definitions formulated by the Alignment of Transcatheter Aortic-Valve Neo-Commissures Consortium, modified to rely on intraprocedural transesophageal echocardiography rather than postprocedural computed tomography scans. The consortium schema categorizes commissural alignment as an angular deviation between 0 and 15.0 degrees, mild commissural malalignment between 15.1 and 30.0 degrees, moderate malalignment between 30.1 and 45.0 degrees, and severe malalignment between 45.1 and 60.0 degrees.
Beyond doubling the rate of isolated commissural alignment, the Shenoda-Blocker technique achieved coronary alignment in 80.2 percent of patients, accounting for 81 of the 101 prospective cases, compared to 54.5 percent, or 55 of 101 patients, in the control arm. This improvement in coronary alignment was statistically significant, yielding a p-value of less than 0.001 and a 95 percent confidence interval between 0.123 and 0.392. Furthermore, severe commissural malalignment was markedly reduced, occurring in only 3.0 percent of patients, or 3 of 101 cases, managed with the novel protocol, compared to 32.7 percent, or 33 of 101 patients, in the control group, representing a significant reduction favored by a 95 percent confidence interval from 0.189 to 0.404 and a p-value below 0.001.
Analysis of anatomical subsets within the prospective cohort revealed that the technique produced varied results in patients presenting with bicuspid aortic valve morphology. Among the four patients with Sievers type 0 bicuspid valves, outcomes were evenly distributed across categories, with one patient achieving commissural alignment, one exhibiting mild malalignment, one showing moderate malalignment, and one demonstrating severe malalignment. Among six patients with Sievers type 1 bicuspid valves, two achieved commissural alignment, one had mild malalignment, and three displayed moderate malalignment. The authors noted that asymmetric calcification patterns in bicuspid leaflets provide an asymmetric path of resistance during balloon expansion, potentially inducing unexpected rotational forces during stent deployment.
The physical basis of the technique relies on predictable translational torque generated along the Edwards Commander Delivery System as the catheter bends and rotates across the aortic arch. Outlier cases were concentrated primarily among patients with extreme aortic root angulations measuring less than 35 degrees or greater than 65 degrees, where catheter torque proved less predictable, as well as those with severe iliofemoral and aortic vascular tortuosity requiring extensive catheter manipulation. As practical experience with the technique expanded, the surgical team identified a critical procedural refinement: actively reorienting the balloon catheter after navigating the aortic arch to ensure the delivery balloon flush port sits firmly in the 9 o’clock position across the stenotic aortic valve, thereby preserving the planned crimped orientation during final expansion.
The investigators emphasized several methodological limitations, noting that the study was conducted at a single medical center, evaluated only the Edwards SAPIEN balloon-expandable platform, and verified alignment using transesophageal echocardiography rather than postoperative computed tomography. Disclosure statements indicated that author Michael Shenoda serves as a paid consultant and proctor for Edwards Lifesciences, author Joseph Aragon serves as a consultant and proctor for Edwards Lifesciences, Boston Scientific, W. L. Gore and Associates, and Shockwave Medical, and the remaining authors reported no financial conflicts.
Subject of Research: Commissural alignment techniques in balloon-expandable transcatheter aortic valve replacement
Article Title: A Novel Method for Commissural Alignment of Balloon-Expandable Transcatheter Aortic Valve Replacement: The Shenoda-Blocker Commissural Alignment Technique
Article References: Shenoda, M., Blocker, B., Tanner, J., Baay, P., Tedesco, D., Paulsen, M., Shafer, C., Jones, B., & Aragon, J. (2026). A Novel Method for Commissural Alignment of Balloon-Expandable Transcatheter Aortic Valve Replacement: The Shenoda-Blocker Commissural Alignment Technique. Structural Heart, 10(12), Article 101121. https://doi.org/10.1016/j.shj.2026.101121
Image Credits: AI Generated
DOI: 10.1016/j.shj.2026.101121
Keywords: transcatheter aortic valve replacement, commissural alignment, Shenoda-Blocker technique, SAPIEN 3 Ultra Resilia, balloon-expandable heart valves, aortic valve plane, aortic root angulation, transesophageal echocardiogram, coronary alignment, commissural malalignment, Edwards Commander Delivery System, preprocedural computed tomography, bicuspid aortic valves, structural interventional cardiology, 3mensio software, valve crimping orientation
News Source: Ophelia Keating. (November 23, 2026). CT-Guided Crimping Increases Commissural Alignment in Balloon-Expandable Transcatheter Aortic Valve Procedures. Scienmag.